City of Hudson, Ohio  
CD Meeting Agenda - Final  
Architectural & Historic Board of Review  
John Caputo, Chair  
Allyn Marzulla, Vice Chair  
John Workley, Secretary  
Andrew Brown  
Amy Manko  
Françoise Massardier-Kenney  
Jamie Sredinski  
Nicholas Sugar, City Planner  
Lauren Coffman, Associate Planner  
Wednesday, November 12, 2025  
7:30 PM  
Town Hall  
27 East Main Street  
Call To Order  
Roll Call  
I.  
II.  
III.  
Public Comment  
Consent Applications  
IV.  
A.  
198 Aurora St (Historic District)  
Alteration (Roof Replacement)  
Submitted by Michael Penn  
a) Staff recommends approval as submitted.  
Attachments:  
Old Business  
V.  
A.  
2608 Brunswick Ln  
Accessory Structure (Detached Garage)  
Submitted by Dennis Reminder  
a) Staff notes this application was tabled at the October 29, 2025, AHBR  
meeting.  
b) The applicant has submitted revised elevations for the Board to review.  
Staff notes the proposed metal siding material has been revised and siding  
added to match the existing house. Additionally, windows have been added  
to the rear elevation to meet fenestration requirements.  
c) Verify proposed foundational material and if it would match the existing  
house.  
Attachments:  
Legislative History  
10/29/25 Architectural & Historic Board continued  
of Review  
B.  
49 Owen Brown Street (Historic District)  
Addition (Second Story)  
Submitted by WC Gotts  
a) Staff notes that the AHBR reviewed this proposal at the October 29, 2025,  
AHBR meeting. The AHBR continued the application to schedule a site  
visit and receive review and report from the consultant.  
b) A site visit occurred on November 4, 2025.  
c) The consultant report is attached for the Board’s consideration.  
Attachments:  
Legislative History  
10/29/25 Architectural & Historic Board continued  
of Review  
C.  
78 Aurora Street (Historic District)  
Addition (Kitchen, Laundry Room, Elevator, & Garage)  
Submitted by Rebecca Pantuso, Pantuso Architecture  
a) Staff notes that the AHBR reviewed this proposal at the October 8, 2025,  
meeting. The AHBR continued the application to schedule a site visit and  
receive review and report from the consultant.  
b) A site visit occurred on October 21, 2025.  
c) The consultant report is attached for the Board’s consideration.  
Attachments:  
Legislative History  
10/8/25  
Architectural & Historic Board continued  
of Review  
New Business  
VI.  
A.  
34 Ravenna St, Unit 2  
Sign (Wall Sign)  
Submitted by Eric Kuczek  
a) Section V-2 (b) of the Architectural Design Standards state the sign and  
associated lighting fixtures should complement the architecture of the  
building on which it is placed and should be placed in an appropriate  
location on the building façade. If the building design does not clearly  
identify the appropriate placement for a sign panel, then individual letters  
are encouraged unless there is a clear location for adding panels, such as  
establishing one or more repetitive, common architectural features in  
order to create a repetitive sequence.  
b) Question the proposed location of the sign on the building. Staff notes sign  
panels have been approved for this building in the past; however, one has  
not been placed in this specific location.  
Attachments:  
B.  
7542 Darrow Rd  
Sign (Ground Sign)  
Submitted by Scott Kuebler  
a) Staff notes the proposed sign face would replace an existing sign face. The  
existing posts would remain.  
b) The applicant states the sign is aluminum construction with vinyl covering.  
c) Section V-5 of the Architectural Design Standards state “signs shall be  
framed, constructed, and erected so as to complement the overall  
appearance of the building and site as well as the overall appearance of  
the sign”. Suggest a border be applied to the sign to conceal the metal  
screws.  
d) Section V-5(c) of the architectural design standards state “signs should  
have a matte finish, not have a glossy or reflective finish.” Staff notes a  
glossy finish.  
Attachments:  
Legislative History  
10/29/25 Architectural & Historic Board continued  
of Review  
C.  
91 N Oviatt St (Historic District)  
Accessory Structure (Roof Overhang)  
Submitted by Jim Rodstrom  
a) Section III-1(d)(3) of the Architectural Design Standards states “The roof  
of an enclosed accessory building should be the same roof shape as the  
roof of the main structure.” Question the proposed shed roof addition on  
the accessory structure as the main structure has a gable roof.  
b) Question if the proposed roof overhang is centered on the proposed north  
elevation. Staff notes that the proposed work would be to the interior of the  
site.  
c) Question if elevations accurately depict how the proposed roof would meet  
the existing barn roof.  
Attachments:  
D.  
95 Maple Dr (Historic District)  
Alterations (Windows & Door Replacement)  
Submitted by Juliann Nathanson  
a) Staff notes vinyl windows are proposed, as well as metal doors. These  
materials have not been deemed appropriate for this historic district.  
Revise to wood or an aluminum clad wood door and windows.  
b) Question removal of the existing door on the south elevation.  
Attachments:  
E.  
6662 Regal Woods Dr  
Addition (Rear Porch)  
Submitted by Scott Dohner, Dohner Landscaping  
a) Section III-1 (g)(5) of the Architectural Design Standards state that if the  
deck height to grade is greater than 18” skirting or a landscape plan should  
be incorporated. Revise elevations to depict skirting or landscape detail for  
the new proposed deck.  
Attachments:  
F.  
5210 Preserve Ln  
New House (Single-Family Dwelling)  
Submitted by LDA Builders, Inc.  
a) Verify grade line is accurately depicted on the submitted elevations.  
b) Question proposed siding material depicted on the front elevation within  
the recessed porch.  
c) Section IV-3 (e)(4) of the Architectural Design Standards states the  
building shall have a typical window used for most windows. Revise the  
window design to depict a more consistent typical window and grid  
pattern.  
d) Revise elevations to consistently depict gable returns  
e) Section IV-4 (d)(3) of the Architectural Design Standards state that the  
materials used in any mass must be applied consistently on that mass on  
all sides of the structure. Revise elevations to depict consistent wall  
material around the proposed wing.  
f) Section IV-4 (d)(3) of the Architectural Design Standards state that details  
in the main body must be consistently applied throughout all sides of the  
main body. Suggest revising the stone veneer in the front gable to vertical  
siding to meet this requirement.  
g) Question the proposed projection siding on the right-side elevation  
adjacent to the proposed garage doors.  
h) Section IV-4 of the Architectural Design Standards state that large  
expanses of blank wall are to be avoided. Fenestration placement should  
be at a maximum of approximately every 12 feet. Suggest revising the  
right-side elevation to incorporate additional architectural detail to be  
applied in the proposed 2nd story gable to better meet this requirement.  
i) Section IV-4 (f) of the Architectural Design Standards state that details in  
the main body must be consistently applied throughout all sides of the  
main body. Staff notes awnings are only applied to the front elevation.  
j) Spec sheets for all exterior materials.  
Attachments:  
Other Business  
VII.  
Minutes of Previous Architectural & Historic Board of Review Meeting:  
October 8, 2025  
Attachments:  
Minutes of Previous Architectural & Historic Board of Review Meeting:  
October 29, 2025  
Attachments:  
Staff Update  
VIII.  
IX.  